Skip to Main Content »

Search Site

60W 12V with junction box UL

Be the first to review this product

Sign up for price alert

Availability: In stock

Log In Is Required To Obtain Current Price.

Quick Overview

• AC to DC Single Output Switching Power Supply
• Self-contained slim design, wiring connection inside
• UL recognized outdoor class 2
• IP64 rating
• For applications of 
  LED Signage 
  LED Architectural Lighting
  LED Industrial Lighting
  LED Sports Lighting
  LED Cobra Head Lighting

60W 12V with junction box UL

More Views

1.Features

-UL1310,Class 2 compliant;
-Constant voltage output;
-For outdoor or indoor applications;
-Suitable for installing in a wiring raceway;
-Ambient temperature:-25~+40
-Protection: over-voltage, over current and short circuit ,auto-recovery;


2.Wiring Diagram:



3. Installation Guide


3.1 Typical Installation


a. Supplies required:



b. Installation in a raceway:




Step 1 :Assemble the back plates with the liquid tight fittings, put the PLTC cable through and make the connections accordingly.MAKE SURE that the AC and DC cables are connected to their respective terminals.Use screws to mount the back plates to the case. Tighten up thescrews and the fittings to prevent leaking.(Fig3)

Step 2:Put the LED Power Supply into the raceway and mount with screws. (Fig.4)


c.Installation without junction boxes for indoor use: Follow Step 1 in “Installation in a raceway” and mount with screws.


d. Installation with junction boxes for indoor use:




Step 1: Mount the junction box on the wall with screws.
Step 2: Assemble the back plates with the liquid tight fittings, pull the AC input cable through.AC the DC output side, put the PLTC cablethrough and make the connections accordingly. Use screwsto mount both back plates to the case. Put the AC side fitting into the knock-out hole of the junction box, Tighten up the screws and the fittings to prevent leaking and mount the DC power supply to thejunction box. (Fig. 3, Fig. 5)
Step 3: Mount the DC power supply to the wall using the back plate at the DC output side with screws . (Fig. 6)
Step 4: Make the AC connections inside the junction box using electrical wire connectors.(Fig.7)


e. Installation with junction boxes for outdoor use:




Step 1: When installing the DC power supply outdoors, follow the steps in "Installation with junction boxes for indoor use with one condition:The product MUST be installed vertically with the junction box on top. Fail to do so may cause leaking over time.(Fig.8,Fig.9)


3.2 Installation Guide for Aluminum Case with Conduit holes


a. Supplier required:



b. Installation Guide:




Step1: Assemble the liquid tight connectors with the case, put the PLTS cable through and make the connections accordingly,MAKE SURE that the AC and DC cables are connected to their respective terminals.When only one AC connection i sneeded,use an end cap to seal the knock-out hole.(Fig.12.Fig.13)

Step2: Use screws to mount both back plates to the DC power supply.Then mount the whole unit onto the wall using screws.Tighten up the screws,liquid tight fittings and the conduit to prevent leaking.(Fig.14)

Model no. SPS-60-12
Input voltage 100-132 VAC 50/60 Hz
Max. power 60 W max
Output type Constant voltage
Dimming No
Built-in active PFC No
Power factor Low
Efficiency 78 %
Output voltage 12VDC ± 5%
Output current 5A max
Overload protection 105%-120% hiccup mode, auto-recovery
Withstand voltage I/P~O/P:1.5kVAC, 1 minute
Operating temperature -25~40℃
Installation Outdoor rainproof
IP rating IP 64
Cooling Free air convection
Certificates/standards UL
Connection input/output Input:0.75mm²x3 (18cm) / Output:0.75mm²x2 (18cm)
Dimensions(L*W*H) 15.11"*2.36"*1.5"
Weight(kg) 0.7700
Packing information 20 Pcs/ Carton, G.W 17.4KG